N.I.F. CRU

______________________________________________________________

PRODUCT DESCRIPTION: EFR is a two component 100% solids epoxy primer developed for use as the base coat when performing a power troweled floor application. The outstanding feature of this product is the excellent adhesion characteristics to concrete substrates.

RECOMMENDED FOR: for priming concrete or masonry when power troweling, also suitable as a primer for vertical applications.

SPECIFYING INFORMATION:

SOLIDS BY WEIGHT: the solids by weight for the system mixed = 100% (+, - 2%)

V.O.C. PER GALLON: Part A = 0.0 pounds per gallon, Part B = 0.0 pounds per gallon.

COLORS AVAILABLE: amber clear

RECOMMENDED FILM THICKNESS:

we recommend applying 6-10 mils per coat

THEORETICAL COVERAGE PER GALLON: each mixed gallon when applied at 6-10 mils thick will yield 160 to 267 square feet, depending on porosity and type of substrate.

MIX RATION: the mix ratio is 2 to 1 by volume, ie, two parts A to one part B by volume

PACKAGING INFORMATION: available in 3 gallons kits and 15 gallon kits, a 3 gal kit = 2 gallons part A and 1 gallon part B. A 15 gallon kit = two 5 gallon pails of part A and one 5 gallon pail of part B.

SHELF LIFE: I year

FINISH: gloss ( 60 - 90 at 60 degrees @ Erichsen glossmeter)

ABRASION RESISTANCE: Taber abrasor CS-17 calibrase wheel with 1000 gram load and 500 cycles yields a 41.2 mg loss

FLEXIBILITY: no cracks on a 1/8" mandrel

YIELD COMPRESSIVE STRENGTH:

ASTM D695 with 1/2" x 1/2" x 1" bars at 10% deformation or less = (8, 150 psi)

TENSILE STRENGTH: ASTM D638 with F=2.25", W=0.500", T=0.125", D=4.5", and rate = 0.2"/minute (6,800 psi)

 

 

ULTIMATE ELONGATION: ASTM D638 with F = 2.25", W = 0.500", T = 0.125" and the rate = 0.2"/min (3.6%)

PRIMER: none required

CURE SCHEDULE:

pot life (150 gram mass)......................20-30 minutes

tackfree ......................................................4-6 hours

recoat ..................................................................n/a

light traffic ..........................................................n/a

full cure ......................................................2-7 days

APPLICATION TEMPERATURE: this product should be applied with substrate temperatures above 50 degrees F and below 90 degrees F

IMPACT RESISTANCE: gardner impact, direct and reverse = 60 in.lb. (passed)

HARDNESS: shore D = 67

RESISTANCE TO ELEVATED TEMPERATURES: no slip or flow at 158 degrees F (mil-D-3134J sec 4.6.3.1)

BOND STRENGTH TO CONCRETE: 340 psi (concrete failure - no delamination)

THERMAL SHOCK: 100 cycles freeze/thaw with no loss of adhesion or evidence of deterioration

COMPRESSIVE MODULUS: ASTM D695 with 1/2" x 1/2" x 1" bars at 10% deformation or less = (180,000 psi)

FLEXURAL STRENGTH: ASTM D790 with 1/2" x 1/2" bars spanning 4" = (10,800 psi)

FLEXURAL MODULUS: ASTM D790 with 1/2" x 1/2" bars spanning 4" = (280,000 psi)

TOPCOAT: product can be topcoated with epoxy mortars or vertical mortars.

Physical properties are typical values and not specifications.