MATERIAL SAFETY DATA SHEET
PRODUCT NAME: NIF 65 PART B HMIS CODES: H F R P
PRODUCT CODE: 144 B 2* 3 0 G
===================== SECTION I -- MANUFACTURER IDENTIFICATION ====================
MANUFACTURER’S NAME: NORTHERN INDUSTRIAL FLOORING, INC.
ADDRESS: 8140 W 350 N ANGOLA, IN 46703
EMERGENCY PHONE: CHEMTREC 800-424-9300 INFORMATION PHONE: 800-424-8914
DATE REVISED: 03-19-96 NAME OF PREPARER: HARRY JACKSON
============= SECTION II -- HAZARDOUS INGREDIENTS/SARA III INFORMATION ==============
OCCUPATIONAL EXPOSURE LIMITS VAPOR PRESSURE WEIGHT
HAZARDOUS COMPONENTS CAS NUMBER OSHA PEL ACGI TLV OSHA STEL mm HG @ TEMP PERCENT
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
*XYLENE 1330-20-7 100 PPM 100 PPM 150 PPM N/A 27
*ETHYL BENZENE 100-41-4 100 PPM 100 PPM 125 PPM N/A 1
TRIETHYLENE TETRAMINE 112-24-3 NONE NONE NONE N/A
POLYAMIDE RESIN UNKNOWN NONE NONE NONE N/A
pigment-the chemical identity is a trade secret NONE 10mg/m3 10mg/m3 6mg/m3 N/A
AROMATIC PETROLEUM DISTILLATES 64742--956 100 PPM 100 PPM NONE N/A
TRIS DIMETHYLAMINOMETHYL-
PHENOL 90-72-2 NONE NONE NONE N/A
filler-the chemical identity is a trade secret NONE 20mppcp 20mppcp none N/A
extender-the chemical identity is a trade secret NONE 20mg/m3 20mg/m3 20mg/m3 N/A
*BUTANOL NORMAL 71-36-3 50 PPM 50 PPM NONE 4.4 58F 2
* Indicates toxic chemical(s) subject to the reporting requirements of section 313 of Title III and of 40 CFR 372 are present.
(ACGIH STEL = 150 FOR XYLENE). (BUTANOL: OSHA CEILING = 50 PPM, TVA-SKIN = 50 PPM). (ETHYL BENZENE ACGIH
STEL - 125 PPM). FOLLOW TSCA 8(d) 40 CFR 47 FR 387: RCRA 40 CFR 261; CWA 311 (b)(2)(a) 40 CFR 116,117 GUIDELINES
================ SECTION III -- PHYSICAL/CHEMICAL CHARACTERISTICS ==================
BOILING RANGE:
144 to 243 Deg F SPECIFIC GRAVITY (H2O=1): 1.4VAPOR DENSITY: N/A EVAPORATION RATE: N/A
SOLUBILITY IN WATER: NEGLIGIBLE
APPEARANCE AND ODOR: LOW VISCOSITY LIQUID IN VARYING COLORS - SOLVENT ODOR
================== SECTION IV -- FIRE AND EXPLOSION HAZARD DATA ====================
FLASH POINT: 79 F METHOD USED: SETA FLASH
FLAMMABLE LIMITS IN AIR BY VOLUME - LOWER: N/A UPPER: N/A
EXTINGUISHING MEDIA: FOAM, ALCOHOL FOAM, CO2,DRY CHEMICAL
SPECIAL FIREFIGHTING PROCEDURES
DO NOT ENTER CONFINED FIRE AREA WITHOUT FULL BUNKER GEAR INCLUDING A POSITIVE PRESSURE NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS. COOL ALL FIRE EXPOSED CONTAINERS WITH WATER. PRESENCE OF SOLVENTS IN PRODUCT
MAY REQUIRE GROUNDING.
UNUSUAL FIRE AND EXPLOSION HAZARDS
IF FIRE OCCURS, SOLVENTS MAY PRODUCE EXCESSIVE PRESSURE. SEALED DRUMS MAY RUPTURE AND IGNITE. VAPORS ARE HEAVIER THAN AIR AND MAY TRAVEL ALONG THE GROUND AND IGNITE BY ANY SOURCE OF IGNITION. NEVER USE A CUTTING OR WELDING TORCH NEAR CONTAINERS (EVEN EMPTY). ALL 5 GALLON AND LARGER CONTAINERS SHOULD BE GROUNDED BEFORE TRANSFERRING MATERIAL.