MATERIAL SAFETY DATA SHEET

 

PRODUCT NAME: NIF 65 PART A HMIS CODES: H F R P

PRODUCT CODE: 144A 2* 3 0 G

 

===================== SECTION I -- MANUFACTURER IDENTIFICATION ====================

MANUFACTURER’S NAME: NORTHERN INDUSTRIAL FLOORING, INC.

ADDRESS: 8140 W 350 N ANGOLA, IN 46703

EMERGENCY PHONE: CHEMTREC 800-424-9300 INFORMATION PHONE: 800-424-8914

DATE REVISED: 03-19-96 NAME OF PREPARER: HARRY JACKSON

 

============= SECTION II -- HAZARDOUS INGREDIENTS/SARA III INFORMATION ==============

OCCUPATIONAL EXPOSURE LIMITS VAPOR PRESSURE WEIGHT

HAZARDOUS COMPONENTS CAS NUMBER OSHA PEL ACGI TLV OSHA STEL mm HG @ TEMP PERCENT

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

SOLID EPOXY RESIN 25036-25-3 NONE NONE NONE N/A

*METHYL ISOBUTYL KETONE 108-10-1 50PPM 50PPM 75PPM N/A 13

*XYLENE 1330-20-7 100 PPM 100 PPM 150 PPM N/A 12

PROPYLENE GLYCOL MONO-

METHYL ETHER 107-98-2 100PPM 100PPM NONE N/A

 

* Indicates toxic chemical(s) subject to the reporting requirements of section 313 of Title III and of 40 CFR 372 are present.

ACGIH STEL = 75 FOR NIBK. ACGIH STEL = 150PPM FOR XYLENE. FOLLOW TSCA 8(d) 40 CFR 47 FR 387: RCRA 40 CFR 261;

CWA 311 (b)(2)(a) 40 CFR 116,117 GUIDELINES. KNOWN HAZARDOUS WASTE NUMBERS ARE XYLENE=U239; MIBK=U161.

 

 

 

 

 

 

 

================ SECTION III -- PHYSICAL/CHEMICAL CHARACTERISTICS ==================

BOILING RANGE: 144 Deg F SPECIFIC GRAVITY (H2O=1): 1.0

VAPOR DENSITY: N/A EVAPORATION RATE: N/A

SOLUBILITY IN WATER: NEGLIGIBLE

APPEARANCE AND ODOR: PALE YELLOW LIQUID WITH SOLVENT ODOR

 

================== SECTION IV -- FIRE AND EXPLOSION HAZARD DATA ====================

FLASH POINT: 66 F METHOD USED: SETA FLASH

FLAMMABLE LIMITS IN AIR BY VOLUME - LOWER: N/A UPPER: N/A

EXTINGUISHING MEDIA: FOAM, ALCOHOL FOAM, CO2,DRY CHEMICAL

SPECIAL FIREFIGHTING PROCEDURES

DO NOT ENTER CONFINED FIRE AREA WITHOUT FULL BUNKER GEAR INCLUDING A POSITIVE PRESSURE NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS. COOL ALL FIRE EXPOSED CONTAINERS WITH WATER. PRESENCE OF SOLVENTS IN PRODUCT

MAY REQUIRE GROUNDING.

UNUSUAL FIRE AND EXPLOSION HAZARDS

IF FIRE OCCURS, SOLVENTS MAY PRODUCE EXCESSIVE PRESSURE. SEALED DRUMS MAY RUPTURE AND IGNITE. VAPORS ARE HEAVIER THAN AIR AND MAY TRAVEL ALONG THE GROUND AND IGNITE BY ANY SOURCE OF IGNITION. NEVER USE A CUTTING OR WELDING TORCH NEAR CONTAINERS (EVEN EMPTY). ALL 5 GALLON AND LARGER CONTAINERS SHOULD BE GROUNDED BEFORE TRANSFERRING MATERIAL.

 