MATERIAL SAFETY DATA SHEET

 

PRODUCT NAME: NIF 55 PART B HMIS CODES: H F R F

PRODUCT CODE: 145 B 2* 3 0 G

 

===================== SECTION I -- MANUFACTURER IDENTIFICATION ====================

MANUFACTURER’S NAME: NORTHERN INDUSTRIAL FLOORING, INC.

ADDRESS: 8140 W 350 N ANGOLA, IN 46703

EMERGENCY PHONE: CHEMTREC 800-424-9300 INFORMATION PHONE: 800-424-8914

DATE REVISED: 02-08-96 NAME OF PREPARER: HARRY JACKSON

 

============= SECTION II -- HAZARDOUS INGREDIENTS/SARA III INFORMATION ==============

OCCUPATIONAL EXPOSURE LIMITS VAPOR PRESSURE WEIGHT

HAZARDOUS COMPONENTS CAS NUMBER OSHA PEL ACGI TLV OSHA STEL mm HG @ TEMP PERCENT

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

*XYLENE 1330-20-7 100PPM 100PPM 150PPM N/A 39

TRIETHYLENE PETRAMINE 112-24-3 NONE NONE N/A

DIMER/TOFA, REACTION

PRODUCTS WITH TETA 68082-29-1 NONE NONE N/A

*BUTANOL NORMAL 71-36-3 50PPM 50PPM NONE 4.4 68F 20

TRIS-2,4,6-DIMETHYLAMINO-

METHYLPHENOL 90-72-2 NONE NONE NONE N/A

DIMETHYLAMINOE-

METHYLPHENOL 25353-55-0 NONE NONE NONE N/A

 

*Indicates toxic chemical(s) subject to the reporting requirements of section 313 of Title III and of 40 CFR 372.

XYLENE ACGIH STEL=150PPM, BUTANOL OSHA TWA(SKIN) = 50PPM, ACGIH TWA (SKIN) = 50 PPM. FOLLOW CWA 311 (B)(2)(A) 40 CFR 116, 117; CWA 304 (A)(1) 45FR 79318; TSCA 8(d) 40 CFR 716 47 FR 387 GUIDNELINES.

 

 

================ SECTION III -- PHYSICAL/CHEMICAL CHARACTERISTICS ==================

BOILING POINT: 144 TO 243 F SPECIFIC GRAVITY (H2O=1): 0.9

VAPOR DENSITY: N/A EVAPORATION RATE: N/A

SOLUBILITY IN WATER: NEGLIGIBLE

APPEARANCE AND ODOR: PALE YELLOW LIQUID WITH SOLVENT ODOR

 

================== SECTION IV -- FIRE AND EXPLOSION HAZARD DATA ====================

FLASH POINT: 74 f METHOD USED: SETA FLASH

FLAMMABLE LIMITS IN AIR BY VOLUME - LOWER: 1.4% UPPER: 11.2%

EXTINGUISHING MEDIA: FOAM, ALCOHOL FOAM, CO2, DRY CHEMICAL

SPECIAL FIREFIGHTING PROCEDURES

DO NOT ENTER CONFINES FIRE AREA WITHOUT FULL BUNKER GEAR INCLUDING A POSITIVE PRESSURE NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS. COOL ALL FIRE EXPOSED CONTAINERS WITH WATER. PRESENCE OF SOLVENTS IN PRODUCT MAY REQUIRE GROUNDING.

UNUSUAL FIRE AND EXPLOSION HAZARDS

IF FIRE OCCURS, SOLVENTS MAY PRODUCE EXCESSIVE PRESSURE. SEALED DRUMS MAY RUPTURE AND IGNITE. VAPORS ARE HEAVIER THAN AIR AND MAY TRAVEL ALONG THE GROUND AND IGNITE BY ANY SOURCE OF IGNITION. NEVER USE A CUTTING OR WELDING TORCH NEAR CONTAINERS (EVEN EMPTY). ALL 5 GALLON AND LARGER CONTAINERS SHOULD BE GROUNDED BEFORE TRANSFERRING MATERIAL.

 

NEXT PAGE