MATERIAL SAFETY DATA SHEET

 

PRODUCT NAME: EFR MORTOR PART A HMIS CODES: H F R P

PRODUCT CODE: 110 A 1* 1 0 G

 

===================== SECTION I -- MANUFACTURER IDENTIFICATION ====================

MANUFACTURER’S NAME: NORTHERN INDUSTRIAL FLOORING, INC.

ADDRESS: 8140 W 350 N ANGOLA, IN 46703

EMERGENCY PHONE: CHEMTREC 800-424-9300 INFORMATION PHONE: 800-424-8914

DATE REVISED: 02-08-96 NAME OF PREPARER: HARRY JACKSON

 

============= SECTION II -- HAZARDOUS INGREDIENTS/SARA III INFORMATION ==============

OCCUPATIONAL EXPOSURE LIMITS VAPOR PRESSURE WEIGHT

HAZARDOUS COMPONENTS CAS NUMBER OSHA PEL ACGI TLV OSHA STEL mm HG @ TEMP PERCENT

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

MODIFIED DIGLYCIDYL ETHER OR

BISPHENOL A 25068-38-6 NONE NONE NONE 1.0 356F

ALKYL GLYCIDYL ETHER 68609-97-2 NONE NONE NONE N/A

FORMALDAHYDE POLYMER

WITH TOLUENE 25155-81-1 NONE NONE NONE N/A

*TOLUENE 108-88-3 100PPM 100PPM NONE 1.0 -26F <0.5%

BENZYL ALCOHOL 100-51-6 NONE NONE NONE 1.0 136F

*GLYCOL ETHER 2-

BUTOZYETHANL 111-76-2 25PPM 25PPM NONE 10.0 97F <0.5%

STODDARD SOLVENT 8052-41-3 100PPM 100PPM NONE 2.0 68F

N/A

1,3,5-TRIMETHYL BENZENE 108-67-8 NONE NONE NONE 1.0 48F

*CUMENE 98-82-8 50PPM 50PPM 100PPMM 1.0 37F <0.5%

*XYLENE 1330-20-7 100PPM 100PPM 150PPM 5.1 68F <0.5%

*ISOBUTYL ALCOHOL 78-83-1 50PPM 50PPM NONE 1.0 16F <0.5%

*Indicates toxic chemical(s) subject to the reporting requirements of section 313 of Title III and of 40 CFR 372.

 

================ SECTION III -- PHYSICAL/CHEMICAL CHARACTERISTICS ==================

BOILING POINT: 200 TO 401 DEG F SPECIFIC GRAVITY (H2O=1): 1.1

VAPOR DENSITY: N/A EVAPORATION RATE: N/A

SOLUBILITY IN WATER: NEGLIGIBLE

APPEARANCE AND ODOR: LOW VISCOSITY LIQUID IN BOTH CLEAR AND COLORS

 

================== SECTION IV -- FIRE AND EXPLOSION HAZARD DATA ====================

FLASH POINT: 200+F METHOD USED: SETA FLASH

FLAMMABLE LIMITS IN AIR BY VOLUME - LOWER: N/A UPPER: N/A

EXTINGUISHING MEDIA: FOAM, ALCOHOL FOAM, CO2, DRY CHEMICAL, WATER FOG

SPECIAL FIREFIGHTING PROCEDURES

DO NOT ENTER CONFINES FIRE AREA WITHOUT FULL BUNKER GEAR INCLUDING A POSITIVE PRESSURE NIOSH APPROVED SELF-CONTAINED BREATHING APPARATUS. COOL ALL FIRE EXPOSED CONTAINERS WITH WATER.

UNUSUAL FIRE AND EXPLOSION HAZARDS

NO UNUSUAL FIRE HAZARDS KNOWN.

 

NEXT PAGE